17 Jan
2011
17 Jan
'11
10:30 a.m.
Hello Stefano,
On Mon, 17 Jan 2011 10:00:51 +0100 Stefano Babic sbabic@denx.de wrote:
On 01/16/2011 07:17 PM, Anatolij Gustschin wrote:
The MXC SPI driver didn't calculate the SPI clock up to now and just used lowest possible divider 512 for DATA RATE in the control register. This results in very low transfer rates.
Hi August,
I sent last friday a patch for mxc_spi.c, too, adding support for mx35, and the two patches now conflict. Is it ok for you if I rebase your patch on top of mine and I post it again ?
Yes, it is ok.
Thanks, Anatolij
-- DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: +49-8142-66989-0 Fax: +49-8142-66989-80 Email: office@denx.de