Dear Wolfgang Denk,
I have tried with Latest u-boot. ( 2009.03-rc1-00000-g00cc559 ). Still not out of trouble.
Here the condition is worse. It gives machine Check Exception and reboots, repeatedly. Some times hangs at "PCi Scan Display" , else after Displaying *"Net: No ethernet found* " .
The case is same even if there's no PCI card inserted. So it like some modification not complete. Any suggestion is appreciated. Mine is a Sequoia board with 2 PCI slts. (I am testing with the Nand-Booting Option, as I dont have a flash programmer for NOR) .
In the old version , I was getting the u-boot prompt, but not always. The new U-Boot hangs as follows.
U-Boot 2009.03-rc1-00000-g00cc559 (Feb 27 2009 - 16:53:12)
CPU: AMCC PowerPC 440EPx Rev. A at 528 MHz (PLB=132, OPB=66, EBC=66 MHz) Security/Kasumi support Bootstrap Option H - Boot ROM Location I2C (Addr 0x52) Internal PCI arbiter enabled, PCI async ext clock used 32 kB I-Cache 32 kB D-Cache Board: Sequoia - AMCC PPC440EPx Evaluation Board, Rev. F, PCI=66 MHz I2C: ready DTT: 1 is 26 C DRAM: 256 MB FLASH: 64 MB NAND: 32 MiB *** Warning - bad CRC, using default environment
PCI: Bus Dev VenId DevId Class Int USB: Host(int phy) Device(ext phy) Net: No ethernet found.
Any suggestion is appreciated. Has anybody got the SATA-PCI working before on PowerPC, or similar situation.
Regards, Ren
Regards, Renjith.
On Thu, Feb 26, 2009 at 5:09 PM, Wolfgang Denk wd@denx.de wrote:
Dear renjith kumar,
In message a8474bd70902260249i12141802j28a1865137d98da1@mail.gmail.com you wrote:
I have u-boot 1.3.1 installed in a sequoia board with ppc4xxEPx. The "pci" command lists out normal PCI cards in the prompt. (Bridge, Multimedia etc.).
But When I use a PCI-SATA card, the s/m gets hangs, most of the time. Else it will not list out the Device in the "pci" command.
In the first step, please update U-Boot and use a recent verison, i. e. v2009.03-rc1; then test again.
Best regards,
Wolfgang Denk
-- DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd@denx.de You can only live once, but if you do it right, once is enough.