On 9/14/21 7:42 PM, Pratyush Yadav wrote:
On 14/09/21 05:22AM, Marek Vasut wrote:
Wait for the read/write transfer finish bit get actually cleared, this does not happen immediately on at least SoCFPGA Gen5.
Signed-off-by: Marek Vasut marex@denx.de Cc: Jagan Teki jagan@amarulasolutions.com Cc: Vignesh R vigneshr@ti.com Cc: Pratyush Yadav p.yadav@ti.com
drivers/spi/cadence_qspi_apb.c | 17 +++++++++++++++++ 1 file changed, 17 insertions(+)
diff --git a/drivers/spi/cadence_qspi_apb.c b/drivers/spi/cadence_qspi_apb.c index 429ee335db6..2cdf4c9c9f8 100644 --- a/drivers/spi/cadence_qspi_apb.c +++ b/drivers/spi/cadence_qspi_apb.c @@ -858,6 +858,14 @@ cadence_qspi_apb_indirect_read_execute(struct cadence_spi_plat *plat, writel(CQSPI_REG_INDIRECTRD_DONE, plat->regbase + CQSPI_REG_INDIRECTRD);
- /* Check indirect done status */
- ret = wait_for_bit_le32(plat->regbase + CQSPI_REG_INDIRECTRD,
CQSPI_REG_INDIRECTRD_DONE, 0, 10, 0);
- if (ret) {
printf("Indirect read clear completion error (%i)\n", ret);
goto failrd;
- }
Huh, this is strange. I would expect the bit to clear immediately since it doesn't really do any operation on the flash. How long does it usually take to clear? If you don't wait for it to clear does anything break?
Often it does clear immediately, but there were a few odd cases where it did not happen right away, in which case I had transfer corruption.