Dear Heiko Schocher,
In message 4C19AC34.3020308@denx.de you wrote:
r12 is used for accessing the GOT not r14. Fix this in the comment.
Signed-off-by: Heiko Schocher hs@denx.de
include/ppc_asm.tmpl | 2 +- 1 files changed, 1 insertions(+), 1 deletions(-)
Applied, thanks.
Best regards,
Wolfgang Denk
--