+ Tom
On Wednesday 02 November 2022 09:58:10 Stefan Roese wrote:
Hi Pali,
added Marek to Cc
On 01.11.22 23:57, Pali Rohár wrote:
On Sunday 09 October 2022 14:34:55 Pali Rohár wrote:
On Friday 02 September 2022 21:56:07 Pali Rohár wrote:
On Wednesday 03 August 2022 08:48:39 Stefan Roese wrote:
On 02.08.22 12:06, Pali Rohár wrote:
Remove identify wrapper functions.
Signed-off-by: Pali Rohár pali@kernel.org
Reviewed-by: Stefan Roese sr@denx.de
Any more comments? Or could it be merged?
PING after another month?
PING?
Marek, could you please take a look? This patch is delegated to you in patchworks:
http://patchwork.ozlabs.org/project/uboot/patch/20220802100655.17965-1-pali@...
Thanks, Stefan
Thanks, Stefan
drivers/gpio/gpio-rcar.c | 15 ++------------- 1 file changed, 2 insertions(+), 13 deletions(-)
diff --git a/drivers/gpio/gpio-rcar.c b/drivers/gpio/gpio-rcar.c index 138801850d3e..ba00bb459679 100644 --- a/drivers/gpio/gpio-rcar.c +++ b/drivers/gpio/gpio-rcar.c @@ -130,20 +130,9 @@ static int rcar_gpio_get_function(struct udevice *dev, unsigned offset) return GPIOF_INPUT; } -static int rcar_gpio_request(struct udevice *dev, unsigned offset,
const char *label)
-{
- return pinctrl_gpio_request(dev, offset, label);
-}
-static int rcar_gpio_free(struct udevice *dev, unsigned offset) -{
- return pinctrl_gpio_free(dev, offset);
-}
- static const struct dm_gpio_ops rcar_gpio_ops = {
- .request = rcar_gpio_request,
- .rfree = rcar_gpio_free,
- .request = pinctrl_gpio_request,
- .rfree = pinctrl_gpio_free, .direction_input = rcar_gpio_direction_input, .direction_output = rcar_gpio_direction_output, .get_value = rcar_gpio_get_value,
Viele Grüße, Stefan Roese
-- DENX Software Engineering GmbH, Managing Director: Wolfgang Denk HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-51 Fax: (+49)-8142-66989-80 Email: sr@denx.de
Viele Grüße, Stefan Roese