Felix,
nice to hear that your problem is fixed.
Since I'm using VSC8601 PHY with RGMII interface this looks like a different issue.
Cheers, André
On Tue, 2010-06-22 at 23:04 +0300, Felix Radensky wrote:
Hi,
eTSEC2 is unusable with TOT master on P2020RDB RevC. The following example demonstrates the problem:
=> setenv ethact eTSEC2 => ping 10.0.0.10 Waiting for PHY auto negotiation to complete...... TIMEOUT ! eTSEC2: No link.
eTSEC2 on P2020RDB is connected to Vitesse SGMII PHY VSC8221.
Git bisect shows that the problem was introduced by the following commit:
46e91674fb4b6d06c6a4984c0b5ac7d9a16923f4 is first bad commit commit 46e91674fb4b6d06c6a4984c0b5ac7d9a16923f4 Author: Peter Tyser ptyser@xes-inc.com Date: Tue Nov 3 17:52:07 2009 -0600
tsec: Force TBI PHY to 1000Mbps full duplex in SGMII mode
Reverting this commit makes the problem go away.
Felix.