1 Aug
2008
1 Aug
'08
12:41 p.m.
In message 18768421.post@talk.nabble.com you wrote:
The above is Because of Below Reasons.
- According to ARM Dual-Timer Module (SP804) TRM (ARM DDI0271),
---Timer Value Register @ TIMER Base + 4 is Read-only. So removed code which writes to this register ---Prescale Value (Bits 3-2 of TIMER Control register) can only be one of 00,01,10. The Value 11 is undefined. So This Patch Changes it to 00.
Please include such information with the patch it refers to.
Best regards,
Wolfgang Denk
--
DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd@denx.de
Nearly everyone is in favor of going to heaven but too many are
hoping they'll live long enough to see an easing of the entrance
requirements. Never appeal to a man's "better nature." he might not
have one.