On 12.12.2018, at 01:57, Christoph Muellner christoph.muellner@theobroma-systems.com wrote:
This patch eliminates the non-standard entries "rockchip,pwm_id" and "rockchip,pwm_voltage". They are neither documented nor read out by any driver.
Additionally it introduces the entry regulator-init-microvolt and sets it to 900 mV, which is the default target value for VDD_LOG.
Signed-off-by: Christoph Muellner christoph.muellner@theobroma-systems.com
Reviewed-by: Philipp Tomsich philipp.tomsich@theobroma-systems.com