Hi Rup,
On Wednesday 24 March 2010 12:22:02 Rupjyoti Sarmah wrote:
440EPx fixed bootstrap options A, B, D, and E sets PLL FWDVA to a value =
- This results in the PLLOUTB being greater than the CPU clock frequency
resulting unstable 440EPx operation resulting in various software hang conditions.
This patch reprograms the FWDVA satisfying the requirement of setting FWDVB to a value greater than 1 while using one of the four deafult bootstrap options.
Applied to u-boot-ppc4xx/master. Thanks.
Cheers, Stefan