Hello,
On 08/07/2015 10:43 AM, Peng Fan wrote:
We do not need that "regulator-name" property must be provided in dts. If "regulator-name" property is not provided in dts, node name will chosen for settings '.name' field of uc_pdata.
Signed-off-by: Peng Fan Peng.Fan@freescale.com Cc: Przemyslaw Marczak p.marczak@samsung.com Cc: Simon Glass sjg@chromium.org
Changes v3: Keep "regulator-name = "VDD_MMC_1.8V"; (must be unique for proper bind)" addressing Przemyslaw's comments.
Changes v2: New patch. Update comments for regulator-name property.
doc/device-tree-bindings/regulator/regulator.txt | 19 ++++++++----------- include/power/regulator.h | 1 + 2 files changed, 9 insertions(+), 11 deletions(-)
diff --git a/doc/device-tree-bindings/regulator/regulator.txt b/doc/device-tree-bindings/regulator/regulator.txt index 68b02a8..2cf4b9d 100644 --- a/doc/device-tree-bindings/regulator/regulator.txt +++ b/doc/device-tree-bindings/regulator/regulator.txt @@ -15,15 +15,8 @@ For the node name e.g.: "prefix[:alpha:]num { ... }":
Example the prefix "ldo" will pass for: "ldo1", "ldo@1", "LDO1", "LDOREG@1"...
-Required properties: -- regulator-name: a string, required by the regulator uclass
-Note -The "regulator-name" constraint is used for setting the device's uclass -platform data '.name' field. And the regulator device name is set from -it's node name.
- Optional properties:
+- regulator-name: a string, required by the regulator uclass
- regulator-min-microvolt: a minimum allowed Voltage value
- regulator-max-microvolt: a maximum allowed Voltage value
- regulator-min-microamp: a minimum allowed Current value
@@ -31,6 +24,12 @@ Optional properties:
- regulator-always-on: regulator should never be disabled
- regulator-boot-on: enabled by bootloader/firmware
+Note +The "regulator-name" constraint is used for setting the device's uclass +platform data '.name' field. And the regulator device name is set from +it's node name. If "regulator-name" is not provided in dts, node name +is chosen for setting the device's uclass platform data '.name' field.
Other kernel-style properties, are currently not used.
Note:
@@ -41,10 +40,8 @@ For the regulator autoset from constraints, the framework expects that:
Example: ldo0 {
- /* Mandatory */
- regulator-name = "VDDQ_EMMC_1.8V";
- /* Optional */
- regulator-name = "VDDQ_EMMC_1.8V"; regulator-min-microvolt = <1800000>; regulator-max-microvolt = <1800000>; regulator-min-microamp = <100000>;
diff --git a/include/power/regulator.h b/include/power/regulator.h index 0152290..1a51c3f 100644 --- a/include/power/regulator.h +++ b/include/power/regulator.h @@ -46,6 +46,7 @@
- Note: For the proper operation, at least name constraint is needed, since
- it can be used when calling regulator_get_by_platname(). And the mandatory
- rule for this name is, that it must be globally unique for the single dts.
- If regulator-name property is not provided, node name will be chosen.
- Regulator bind:
- For each regulator device, the device_bind() should be called with passed
Applied to: u-boot-pmic.
Best regards,