Dear York Sun,
In message 1363973369-26110-3-git-send-email-yorksun@freescale.com you wrote:
From: Shaohui Xie Shaohui.Xie@freescale.com
TN80xx has same PHY ID as TN2020, but it needs different setting to register 30.93 which used to select line, so we read register 30.32 which has bit 15:12 to indicate PHY hardware version, for TN20xx we will get 3 or 2, for TN80xx we will get 5 or 4.
Signed-off-by: Shaohui Xie Shaohui.Xie@freescale.com
drivers/net/phy/teranetics.c | 15 +++++++++++++-- 1 file changed, 13 insertions(+), 2 deletions(-)
CHECK: braces {} should be used on all arms of this statement #136: FILE: drivers/net/phy/teranetics.c:46: + if (phy_hwversion <= 3) { [...] + } else [...]
Best regards,
Wolfgang Denk
--
DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd@denx.de
Even if you can deceive people about a product through misleading
statements, sooner or later the product will speak for itself.