5 Jun
2008
5 Jun
'08
12:06 a.m.
In message 1210928766-31604-1-git-send-email-sr@denx.de you wrote:
On AD7414 the first value upon bootup is not read correctly. This is most likely because of the 800ms update time of the temp register in normal update mode. To get current values each time we issue the "dtt" command including upon powerup we switch into one-short mode.
This patch fixes the problem on AD7414 equipped boards (Sequoia, Canyonlands etc), that temp value printed in the bootup log was incorrect.
Signed-off-by: Stefan Roese sr@denx.de
drivers/hwmon/lm75.c | 13 +++++++++++++ 1 files changed, 13 insertions(+), 0 deletions(-)
Applied, thanks.
Best regards,
Wolfgang Denk
--
DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd@denx.de
Real computer scientists don't comment their code. The identifiers