On Tue, 9 Sep 2008, Wolfgang Denk wrote:
diff --git a/board/trab/tsc2000.c b/board/trab/tsc2000.c index 382a85b..f13a5a9 100644 --- a/board/trab/tsc2000.c +++ b/board/trab/tsc2000.c @@ -27,6 +27,7 @@
#include <common.h> #include <s3c2400.h> +#include <div64.h> #include "tsc2000.h"
#include "Pt1000_temp_data.h" @@ -332,6 +333,7 @@ void tsc2000_reg_init (void) int tsc2000_interpolate(long value, long data[][2], long *result) { int i;
unsigned long long val;
/* the data is sorted and the first element is upper
- limit so we can easily check for out-of-band values
@@ -347,10 +349,10 @@ int tsc2000_interpolate(long value, long data[][2], long *result) result in 'long long'. */
- *result = data[i-1][1] +
((unsigned long long)(data[i][1] - data[i-1][1])
* (unsigned long long)(value - data[i-1][0]))
/ (data[i][0] - data[i-1][0]);
- val = ((unsigned long long)(data[i][1] - data[i-1][1])
* (unsigned long long)(value - data[i-1][0]));
- do_div(val, (data[i][0] - data[i-1][0]));
Looking at how do_div() is defined, and it handles its parameters carefully, one shouldn't need the extra parenthesis here, i.e.,
+ do_div(val, data[i][0] - data[i-1][0]);
should be enough.
*result = data[i-1][1] + val;
return 0;
} diff --git a/cpu/arm1176/s3c64xx/interrupts.c b/cpu/arm1176/s3c64xx/interrupts.c index 8356ae4..e34369f 100644 --- a/cpu/arm1176/s3c64xx/interrupts.c +++ b/cpu/arm1176/s3c64xx/interrupts.c @@ -41,6 +41,7 @@ #include <common.h> #include <asm/proc-armv/ptrace.h> #include <s3c6400.h> +#include <div64.h>
static ulong timer_load_val;
@@ -148,7 +149,9 @@ void reset_timer(void)
ulong get_timer_masked(void) {
- return get_ticks() / (timer_load_val / (100 * CFG_HZ));
- unsigned long long res = get_ticks();
- do_div (res, (timer_load_val / (100 * CFG_HZ)));
Same here.
+ do_div (res, timer_load_val / (100 * CFG_HZ));
Thanks Guennadi --- Guennadi Liakhovetski, Ph.D.
DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: +49-8142-66989-0 Fax: +49-8142-66989-80 Email: office@denx.de