18 Jan
2011
18 Jan
'11
12:20 p.m.
On 01/16/2011 07:17 PM, Anatolij Gustschin wrote:
We need to shift only one time in each cycle in the swapping loop for unaligned tx case. Currently two byte shift operations are performed in each loop cycle causing zero gaps in the transmited data, so not all data scheduled for transmition is actually transmited.
Tested on a mx35pdk.
Tested-by: Stefano Babic sbabic@denx.de
Best regards, Stefano Babic
--
=====================================================================
DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: +49-8142-66989-0 Fax: +49-8142-66989-80 Email: office@denx.de
=====================================================================