16 Oct
2023
16 Oct
'23
11:23 a.m.
From: Fabio Estevam festevam@denx.de Since commit 4fcba5d556b4 ("regulator: implement basic reference counter") the return value of regulator_set_enable() may be EALREADY or EBUSY for fixed/GPIO regulators. Switch to using the more relaxed regulator_set_enable_if_allowed() to continue if regulator already was enabled or disabled. This fixes the following error when running the 'ums' command: => ums 0 mmc 0 UMS: LUN 0, dev mmc 0, hwpart 0, sector 0x0, count 0xece000 Error enabling VBUS supply g_dnl_register: failed!, error: -114 g_dnl_register failed Signed-off-by: Fabio Estevam festevam@denx.de Reviewed-by: Marek Vasut marex@denx.de
Applied to u-boot-imx, master, thanks !
Best regards, Stefano Babic
--
=====================================================================
DENX Software Engineering GmbH, Managing Director: Erika Unter
HRB 165235 Munich, Office: Kirchenstr.5, 82194 Groebenzell, Germany
Phone: +49-8142-66989-53 Fax: +49-8142-66989-80 Email: sbabic@denx.de
=====================================================================