Set default critical/alert temperature and enabling monoitoring. Without calling imx_tmu_enable_msite() monitoring will not be enabled and read_temperature will return 0. Additionally without setting alert temperature will cause imx_tmu_get_temp() to spin indefiniately thinking the system needs to cool. This resolves the board spinning endlessly when enabling IMX_TMU in the SPL. Reviewed-by: Fabio Estevam festevam@gmail.com Signed-off-by: Tim Harvey tharvey@gateworks.com
Applied to u-boot-imx, master, thanks !
Best regards, Stefano Babic
--
=====================================================================
DENX Software Engineering GmbH, Managing Director: Wolfgang Denk
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: +49-8142-66989-53 Fax: +49-8142-66989-80 Email: sbabic@denx.de
=====================================================================