Hello Oleksandr,
Am 01.02.2017 um 19:52 schrieb Oleksandr Tymoshenko:
Tom Rini (trini@konsulko.com) wrote:
On Tue, Jan 31, 2017 at 05:15:20PM -0800, Oleksandr Tymoshenko wrote:
Default fcr value is initialized in ns16550_serial_ofdata_to_platdata but this function is only called if OF_CONTROL option is enabled while the field is used whenever DM_SERIAL is set. So for configs that do not have OF_CONTROL default fcr value is set to zero which leads to loosing characters when serial port input is faster than reading routine i.e. when copy-pasting long line to U-Boot prompt.
As a fix initialize fcr field in probe method
Signed-off-by: Oleksandr Tymoshenko gonzo@bluezbox.com Cc: Marek Vasut marex@denx.de Cc: Tom Rini trini@konsulko.com Cc: Simon Glass sjg@chromium.org
Are you still seeing this with v2017.03-rc1? Thanks!
No, this bug is not reproducible on v2017.03-rc1, I believe 17fa032671 fixed it. Not sure how I missed that patch I am pretty sure I tested my BBB with master branch.
Yes commit 17fa032671 fixed this issue. How do you test? You must type very fast, or copy&paste a long command ...
bye, Heiko