Hi Marek,
Add support for fetching the image position in RAM from control DT rather than hard-coding it. While doing so, return the return value of spl_parse_header_image() to make it possible to test application of DTOs on U-Boot's control DT.
Signed-off-by: Marek Vasut marex@denx.de Cc: Pantelis Antoniou pantelis.antoniou@konsulko.com Cc: Simon Glass sjg@chromium.org
common/spl/spl_ram.c | 21 ++++++++++++++++----- 1 file changed, 16 insertions(+), 5 deletions(-)
diff --git a/common/spl/spl_ram.c b/common/spl/spl_ram.c index fa8c768773..c88d09ba04 100644 --- a/common/spl/spl_ram.c +++ b/common/spl/spl_ram.c @@ -14,12 +14,14 @@ #include <binman_sym.h> #include <mapmem.h> #include <spl.h> -#include <libfdt.h> +#include <fdtdec.h>
#ifndef CONFIG_SPL_LOAD_FIT_ADDRESS # define CONFIG_SPL_LOAD_FIT_ADDRESS 0 #endif
+DECLARE_GLOBAL_DATA_PTR;
static ulong spl_ram_load_read(struct spl_load_info *load, ulong sector, ulong count, void *buf) { @@ -33,7 +35,12 @@ static int spl_ram_load_image(struct spl_image_info *spl_image, struct spl_boot_device *bootdev) { struct image_header *header;
- unsigned image_offs;
+#if CONFIG_IS_ENABLED(OF_CONTROL) && !CONFIG_IS_ENABLED(OF_PLATDATA)
- image_offs = fdtdec_get_config_int(gd->fdt_blob,
"u-boot,spl-image-offset", 0); +#endif header = (struct image_header *)CONFIG_SPL_LOAD_FIT_ADDRESS;
#if defined(CONFIG_SPL_DFU_SUPPORT) @@ -48,7 +55,7 @@ static int spl_ram_load_image(struct spl_image_info *spl_image, debug("Found FIT\n"); load.bl_len = 1; load.read = spl_ram_load_read;
spl_load_simple_fit(spl_image, &load, 0, header);
return spl_load_simple_fit(spl_image, &load, 0,
header); } else { ulong u_boot_pos = binman_sym(ulong, u_boot_any, pos); @@ -64,12 +71,16 @@ static int spl_ram_load_image(struct spl_image_info *spl_image, * No binman support or no information. For now, fix it * to the address pointed to by U-Boot. */
u_boot_pos = CONFIG_SYS_TEXT_BASE -
sizeof(struct image_header);
if (image_offs)
u_boot_pos = image_offs;
else
u_boot_pos = CONFIG_SYS_TEXT_BASE -
sizeof(struct
image_u_boot_pos); } header = (struct image_header *)map_sysmem(u_boot_pos, 0);
spl_parse_image_header(spl_image, header);
return spl_parse_image_header(spl_image, header);
}
return 0;
Reviewed-by: Lukasz Majewski lukma@denx.de
Best regards,
Lukasz Majewski
--
DENX Software Engineering GmbH, Managing Director: Wolfgang Denk HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd@denx.de