16 Jul
2020
16 Jul
'20
7:49 p.m.
OF graph endpoint connections must be bidirectional and dtc warn if they are not. i.MX7 based DTs have an error and generate warnings: arch/arm/dts/imx7d-sdb.dtb: Warning (graph_endpoint): /replicator/ports/port@0/endpoint: graph connection to node '/soc/tpiu@30087000/port/endpoint' is not bidirectional arch/arm/dts/imx7d-sdb.dtb: Warning (graph_endpoint): /soc/tpiu@30087000/port/endpoint: graph connection to node '/replicator/ports/port@1/endpoint' is not bidirectional Signed-off-by: Ilko Iliev iliev@ronetix.at
Applied to u-boot-imx, master, thanks !
Best regards, Stefano Babic
--
=====================================================================
DENX Software Engineering GmbH, Managing Director: Wolfgang Denk
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: +49-8142-66989-53 Fax: +49-8142-66989-80 Email: sbabic@denx.de
=====================================================================