On Wed, Feb 1, 2017 at 1:55 PM, ken <Ken Lin> yungching0725@gmail.com wrote:
Apply the previous setting for the reserved bits in SetDes Test and System Mode Control register to avoid the voltage peak issue while we do the IEEE PHY comformance test
Seems reasonable. Was this tested on HW? If so, please add a tested tag.
Thanks, -Joe
drivers/net/phy/atheros.c | 6 ++++++ 1 file changed, 6 insertions(+)
diff --git a/drivers/net/phy/atheros.c b/drivers/net/phy/atheros.c index b34cdd3d87..82fe228604 100644 --- a/drivers/net/phy/atheros.c +++ b/drivers/net/phy/atheros.c @@ -28,6 +28,8 @@ static int ar8021_config(struct phy_device *phydev)
static int ar8031_config(struct phy_device *phydev) {
int regval;
if (phydev->interface == PHY_INTERFACE_MODE_RGMII_TXID || phydev->interface == PHY_INTERFACE_MODE_RGMII_ID) { phy_write(phydev, MDIO_DEVAD_NONE, AR803x_PHY_DEBUG_ADDR_REG,
@@ -44,6 +46,10 @@ static int ar8031_config(struct phy_device *phydev) AR803x_RGMII_RX_CLK_DLY); }
phy_write(phydev, MDIO_DEVAD_NONE, AR803x_PHY_DEBUG_ADDR_REG, AR803x_DEBUG_REG_5);
regval = phy_read(phydev, MDIO_DEVAD_NONE, AR803x_PHY_DEBUG_DATA_REG);
phy_write(phydev, MDIO_DEVAD_NONE, AR803x_PHY_DEBUG_DATA_REG, regval | 0x3C47);
phydev->supported = phydev->drv->features; genphy_config_aneg(phydev);
-- 2.11.0
U-Boot mailing list U-Boot@lists.denx.de http://lists.denx.de/mailman/listinfo/u-boot