6 Jan
2015
6 Jan
'15
2:49 a.m.
On 5 January 2015 at 08:27, Bin Meng bmeng.cn@gmail.com wrote:
If coreboot is built with CONFIG_COLLECT_TIMESTAMPS, use the value of base_time in coreboot's timestamp table as our timer base, otherwise TSC counter value will be used.
Sometimes even coreboot is built with CONFIG_COLLECT_TIMESTAMPS, the value of base_time in the timestamp table is still zero, so we must exclude this case too (this is currently seen on booting coreboot in qemu).
Signed-off-by: Bin Meng bmeng.cn@gmail.com
Changes in v2:
- Fix the CONFIG_COLLECT_TIMESTAMPS typo in the comment block and commit message
Acked-by: Simon Glass sjg@chromium.org