pá 12. 3. 2021 v 14:53 odesílatel Michal Simek michal.simek@xilinx.com napsal:
Condition to setup GQSPI_DFLT_BAUD_RATE_VAL(number 2) in case when baud_rate_val is more then 7 is wrong. There should be really the biggest possible value which is 7. This can be achieve in easier way by enabling calculation till GQSPI_MAX_BAUD_RATE_VAL.
Signed-off-by: Michal Simek michal.simek@xilinx.com
drivers/spi/zynqmp_gqspi.c | 8 ++------ 1 file changed, 2 insertions(+), 6 deletions(-)
diff --git a/drivers/spi/zynqmp_gqspi.c b/drivers/spi/zynqmp_gqspi.c index f8d13d193e30..900cb2610c7f 100644 --- a/drivers/spi/zynqmp_gqspi.c +++ b/drivers/spi/zynqmp_gqspi.c @@ -324,14 +324,10 @@ static int zynqmp_qspi_set_speed(struct udevice *bus, uint speed) if (plat->speed_hz != speed) { /* Set the clock frequency */ /* If speed == 0, default to lowest speed */
while ((baud_rate_val < 8) &&
((plat->frequency /
(2 << baud_rate_val)) > speed))
while (baud_rate_val < GQSPI_MAX_BAUD_RATE_VAL &&
(plat->frequency / (2 << baud_rate_val)) > speed) baud_rate_val++;
if (baud_rate_val > GQSPI_MAX_BAUD_RATE_VAL)
baud_rate_val = GQSPI_DFLT_BAUD_RATE_VAL;
plat->speed_hz = plat->frequency / (2 << baud_rate_val); confr = readl(®s->confr);
-- 2.30.1
Please ignore this patch because it needs to be changed.
Thanks, Michal