On Thu, Jul 1, 2021 at 2:50 AM Tim Harvey tharvey@gateworks.com wrote:
If the FEC is connected to a fixed-link (upstream switch port for example) the phy_of_node should be set to the fixed-link node so that speed and other properties can be found properly.
In addition fix a typo in the debug string.
Signed-off-by: Tim Harvey tharvey@gateworks.com
drivers/net/fec_mxc.c | 6 +++++- 1 file changed, 5 insertions(+), 1 deletion(-)
diff --git a/drivers/net/fec_mxc.c b/drivers/net/fec_mxc.c index 3abf914833..77680491d0 100644 --- a/drivers/net/fec_mxc.c +++ b/drivers/net/fec_mxc.c @@ -1304,7 +1304,11 @@ static int device_get_phy_addr(struct fec_priv *priv, struct udevice *dev) ret = dev_read_phandle_with_args(dev, "phy-handle", NULL, 0, 0, &phandle_args); if (ret) {
debug("Failed to find phy-handle (err = %d\n)", ret);
priv->phy_of_node = ofnode_find_subnode(dev_ofnode(dev),
"fixed-link");
if (ofnode_valid(priv->phy_of_node))
return 0;
debug("Failed to find phy-handle (err = %d)\n", ret); return ret; }
-- 2.17.1
Reviewed-by: Ramon Fried rfried.dev@gmail.com