The driver now unconditionally prints some information that's not universally useful. Replace printf with debug.
Signed-off-by: Alex Marginean alexandru.marginean@nxp.com --- drivers/net/phy/aquantia.c | 24 ++++++++++++------------ 1 file changed, 12 insertions(+), 12 deletions(-)
diff --git a/drivers/net/phy/aquantia.c b/drivers/net/phy/aquantia.c index 2af09907a1..aa0deb1f78 100644 --- a/drivers/net/phy/aquantia.c +++ b/drivers/net/phy/aquantia.c @@ -409,9 +409,9 @@ int aquantia_config(struct phy_device *phydev) fault = phy_read(phydev, MDIO_MMD_VEND1, GLOBAL_FAULT);
if (id != 0) - printf("%s running firmware version %X.%X.%X\n", - phydev->dev->name, (id >> 8), id & 0xff, - (rstatus >> 4) & 0xf); + debug("%s running firmware version %X.%X.%X\n", + phydev->dev->name, (id >> 8), id & 0xff, + (rstatus >> 4) & 0xf);
if (fault != 0) printf("%s fault 0x%04x detected\n", phydev->dev->name, fault); @@ -492,12 +492,12 @@ int aquantia_config(struct phy_device *phydev)
if (usx_an) { reg_val1 |= AQUANTIA_USX_AUTONEG_CONTROL_ENA; - printf("%s: system interface USXGMII\n", - phydev->dev->name); + debug("%s: system interface USXGMII\n", + phydev->dev->name); } else { reg_val1 &= ~AQUANTIA_USX_AUTONEG_CONTROL_ENA; - printf("%s: system interface XFI\n", - phydev->dev->name); + debug("%s: system interface XFI\n", + phydev->dev->name); }
phy_write(phydev, MDIO_MMD_PHYXS, @@ -524,11 +524,11 @@ int aquantia_config(struct phy_device *phydev) val = phy_read(phydev, MDIO_MMD_VEND1, AQUANTIA_RESERVED_STATUS); reg_val1 = phy_read(phydev, MDIO_MMD_VEND1, AQUANTIA_FIRMWARE_ID);
- printf("%s: %s Firmware Version %x.%x.%x\n", phydev->dev->name, - phydev->drv->name, - (reg_val1 & AQUANTIA_FIRMWARE_MAJOR_MASK) >> 8, - reg_val1 & AQUANTIA_FIRMWARE_MINOR_MASK, - (val & AQUANTIA_FIRMWARE_BUILD_MASK) >> 4); + debug("%s: %s Firmware Version %x.%x.%x\n", phydev->dev->name, + phydev->drv->name, + (reg_val1 & AQUANTIA_FIRMWARE_MAJOR_MASK) >> 8, + reg_val1 & AQUANTIA_FIRMWARE_MINOR_MASK, + (val & AQUANTIA_FIRMWARE_BUILD_MASK) >> 4);
return 0; }