25 Nov
2016
25 Nov
'16
8:38 p.m.
On 26 October 2016 at 10:31, Simon Glass sjg@chromium.org wrote:
On 26 October 2016 at 01:12, Keerthy j-keerthy@ti.com wrote:
Currently the specific set ops functions are directly called without any check for voltage limits for a regulator. Check for them and proceed.
Signed-off-by: Keerthy j-keerthy@ti.com
drivers/power/regulator/regulator-uclass.c | 5 +++++ 1 file changed, 5 insertions(+)
Reviewed-by: Simon Glass sjg@chromium.org
Applied to u-boot-rockchip, thanks!