Currently watchdog tries to use dev_read_u32_default to get timeout configuration in case OF_CONTROL is enabled. However, if SPL is built with OF_PLATDATA this has no sense as there is no device tree.
This patch fixes this issue by only use dev_read_u32_default if OF_CONTROL is enabled but OF_PLATDATA is not.
Signed-off-by: Walter Lozano walter.lozano@collabora.com --- include/wdt.h | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-)
diff --git a/include/wdt.h b/include/wdt.h index 5bcff24ab3..dd83dfdd32 100644 --- a/include/wdt.h +++ b/include/wdt.h @@ -130,11 +130,10 @@ static inline int initr_watchdog(void) } }
- if (CONFIG_IS_ENABLED(OF_CONTROL)) { + if (CONFIG_IS_ENABLED(OF_CONTROL) && !CONFIG_IS_ENABLED(OF_PLATDATA)) { timeout = dev_read_u32_default(gd->watchdog_dev, "timeout-sec", WATCHDOG_TIMEOUT_SECS); } - wdt_start(gd->watchdog_dev, timeout * 1000, 0); gd->flags |= GD_FLG_WDT_READY; printf("WDT: Started with%s servicing (%ds timeout)\n",