On Sat, Aug 27, 2011 at 9:51 AM, Eric Bénard eric@eukrea.com wrote:
Hi Joel,
Le 27/08/2011 06:46, Joel A Fernandes a écrit :
The logic is wrong here. I don't remember the polarity, but I do remember that it is xM-A and xM-B that are the oddballs. I believe this is the correct change:
Hi Jason,
LEDAON should be high for HUB power up on xMA and xMB, so in your code snip:
- switch (get_board_revision()) {
- case REVISION_XM_A:
- case REVISION_XM_B:
- twl4030_led_init(TWL4030_LED_LEDEN_LEDBON);
So this should be TWL4030_LED_LEDEN_LEDBON | TWL4030_LED_LEDEN_LEDAON
- break;
- default:
- twl4030_led_init(TWL4030_LED_LEDEN_LEDAON | TWL4030_LED_LEDEN_LEDBON);
and, this should be TWL4030_LED_LEDEN_LEDBON
Am I correct?
LEDA & LEDB are active low Open Drain outputs so enabling LEDAON bit in LEDEN means LEDA output is at low level.
Thanks for resolving that mystery. I just figured out what I thought it should be by looking at the previous default, which should be the new default as well with only XM_A and XM_B are different.