Hi Sherry,
From: Sherry Sun sherry.sun@nxp.com
Because the buffer length of sdp usb request is 65,
Is the value 65 mentioned somewhere (in any doc/spec)?
As fair as I remember other protocols - like DFU use 64B. Do we need here to store extra \0 or \n ?
The 64 bytes are default packet size on EP0.
If I may ask - what user space program do you use? imx_loader (imx_usb) or uuu ?
we have to allocate 65 bytes not 64 bytes. Otherwise there is potential buffer overflow.
So the wMaxPacketSize of fullspeed can't meet the needs. Add HS endpoint descriptor for SDP. Then we can use high speed endpoint, and the SDP device can send packet with 512 byte size.
Signed-off-by: Sherry Sun sherry.sun@nxp.com Signed-off-by: Ye Li ye.li@nxp.com
drivers/usb/gadget/f_sdp.c | 33 ++++++++++++++++++++++++++++++--- 1 file changed, 30 insertions(+), 3 deletions(-)
diff --git a/drivers/usb/gadget/f_sdp.c b/drivers/usb/gadget/f_sdp.c index b1601575e0..532041063a 100644 --- a/drivers/usb/gadget/f_sdp.c +++ b/drivers/usb/gadget/f_sdp.c @@ -157,6 +157,16 @@ static struct usb_endpoint_descriptor in_desc = { .bInterval = 1, };
+static struct usb_endpoint_descriptor in_hs_desc = {
- .bLength = USB_DT_ENDPOINT_SIZE,
- .bDescriptorType =
USB_DT_ENDPOINT, /*USB_DT_CS_ENDPOINT*/ +
- .bEndpointAddress = 1 | USB_DIR_IN,
- .bmAttributes = USB_ENDPOINT_XFER_INT,
- .wMaxPacketSize = 512,
- .bInterval = 1,
Which endpoint do we use in SDP? EP0 or EP1...n ?
+};
static struct usb_descriptor_header *sdp_runtime_descs[] = { (struct usb_descriptor_header *)&sdp_intf_runtime, (struct usb_descriptor_header *)&sdp_hid_desc, @@ -164,6 +174,13 @@ static struct usb_descriptor_header *sdp_runtime_descs[] = { NULL, };
+static struct usb_descriptor_header *sdp_runtime_hs_descs[] = {
- (struct usb_descriptor_header *)&sdp_intf_runtime,
- (struct usb_descriptor_header *)&sdp_hid_desc,
- (struct usb_descriptor_header *)&in_hs_desc,
- NULL,
+};
/* This is synchronized with what the SoC implementation reports */ static struct hid_report sdp_hid_report = { .usage_page = { @@ -489,6 +506,11 @@ static int sdp_bind(struct usb_configuration *c, struct usb_function *f) goto error; }
- if (gadget_is_dualspeed(gadget)) {
/* Assume endpoint addresses are the same for both
speeds */
in_hs_desc.bEndpointAddress =
in_desc.bEndpointAddress;
}
sdp->in_ep = ep; /* Store IN EP for enabling @ setup */
cdev->req->context = sdp;
@@ -526,7 +548,7 @@ static struct usb_request *sdp_start_ep(struct usb_ep *ep) { struct usb_request *req;
- req = alloc_ep_req(ep, 64);
req = alloc_ep_req(ep, 65); debug("%s: ep:%p req:%p\n", __func__, ep, req);
if (!req)
@@ -541,11 +563,15 @@ static int sdp_set_alt(struct usb_function *f, unsigned intf, unsigned alt) { struct f_sdp *sdp = func_to_sdp(f); struct usb_composite_dev *cdev = f->config->cdev;
struct usb_gadget *gadget = cdev->gadget; int result;
debug("%s: intf: %d alt: %d\n", __func__, intf, alt);
- result = usb_ep_enable(sdp->in_ep, &in_desc);
- if (gadget_is_dualspeed(gadget) && gadget->speed ==
USB_SPEED_HIGH)
result = usb_ep_enable(sdp->in_ep, &in_hs_desc);
- else
if (result) return result; sdp->in_req = sdp_start_ep(sdp->in_ep);result = usb_ep_enable(sdp->in_ep, &in_desc);
@@ -591,7 +617,7 @@ static int sdp_bind_config(struct usb_configuration *c) memset(sdp_func, 0, sizeof(*sdp_func));
sdp_func->usb_function.name = "sdp";
- sdp_func->usb_function.hs_descriptors = sdp_runtime_descs;
- sdp_func->usb_function.hs_descriptors = sdp_runtime_hs_descs; sdp_func->usb_function.descriptors = sdp_runtime_descs; sdp_func->usb_function.bind = sdp_bind; sdp_func->usb_function.unbind = sdp_unbind;
@@ -724,6 +750,7 @@ static void sdp_handle_in_ep(struct spl_image_info *spl_image) /* In SPL, allow jumps to U-Boot images */ struct spl_image_info spl_image = {}; spl_parse_image_header(&spl_image, header);
jump_to_image_no_args(&spl_image);
#else /* In U-Boot, allow jumps to scripts */
Best regards,
Lukasz Majewski
--
DENX Software Engineering GmbH, Managing Director: Wolfgang Denk HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-59 Fax: (+49)-8142-66989-80 Email: lukma@denx.de