5 Feb
2008
5 Feb
'08
12:04 a.m.
In message 20071227095654.717B62405E@gemini.denx.de you wrote:
According to the OMAP5912 Serial Interfaces Reference Guide (see http://focus.ti.com/lit/ug/spru760c/spru760c.pdf, page 150), the FIFO_EN enable bit in the FIFO Control Register (FCR) can only be changed when the baud clock is not running, i. e. when both DLL and DLH are set to 0.
Thus make sure that DLL and DLH are 0 when writing the FCR.
Signed-off-by: Wolfgang Denk wd@denx.de
Applied.
Best regards,
Wolfgang Denk
--
DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd@denx.de
"It is better to have tried and failed than to have failed to try,
but the result's the same." - Mike Dennison