20 Mar
2010
20 Mar
'10
6:56 p.m.
Kumar Gala wrote:
From: Jerry Huang Chang-Ming.Huang@freescale.com
To support multiple block read command we must set abort or use auto CMD12. If we booted from eSDHC controller neither of these are used and thus we need to reset the controller to allow multiple block read to function.
Signed-off-by: Jerry Huang Chang-Ming.Huang@freescale.com Signed-off-by: Roy Zang tie-fei.zang@freescale.com
Tested successfully on mx51evk.
Acked-by: Stefano Babic sbabic@denx.de
Regards, Stefano
--
=====================================================================
DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: +49-8142-66989-0 Fax: +49-8142-66989-80 Email: office@denx.de
=====================================================================