Hi there,
On Sep 3, 2013, at 3:50 PM, Przemyslaw Marczak wrote:
According to JEDEC eMMC specification, after data transfer (multiple or single block) host must wait for card ready status. This is done by waiting for command and data lines to be at idle state after transfer. JEDEC does not specify maximum timeout.
Before this change max timeout was 10 ms but in case of UMS
- when system does multiple read/write operations on random
card blocks - timeout causes I/O errors. The timeout has been increased to 200ms after data transfer. For other transfers it stays unchanged.
Tested on Goni and Trats.
Signed-off-by: Przemyslaw Marczak p.marczak@samsung.com Cc: Pantelis Antoniou panto@antoniou-consulting.com
drivers/mmc/sdhci.c | 14 ++++++++++++-- 1 file changed, 12 insertions(+), 2 deletions(-)
diff --git a/drivers/mmc/sdhci.c b/drivers/mmc/sdhci.c index 4261991..c495482 100644 --- a/drivers/mmc/sdhci.c +++ b/drivers/mmc/sdhci.c @@ -121,8 +121,18 @@ int sdhci_send_command(struct mmc *mmc, struct mmc_cmd *cmd, unsigned int timeout, start_addr = 0; unsigned int retry = 10000;
- /* Wait max 10 ms */
- timeout = 10;
/*
* For some commands this function is called with NULL mmc_data
* pointer. One of those is CMD13 - send card status.
* After read/write data transfer or block erase commands - host sends
* CMD13 and is waiting for card ready status with some timeout.
* According to some internal cards operations after those commands
* this time must be increased.
*/
if (data)
timeout = 10; /* ms */
else
timeout = 200;
sdhci_writel(host, SDHCI_INT_ALL_MASK, SDHCI_INT_STATUS); mask = SDHCI_CMD_INHIBIT | SDHCI_DATA_INHIBIT;
-- 1.7.9.5
Can we have a config option for these two values instead of magic numbers?
With the defaults being set at 10 & 200 ms.
Regards
-- Pantelis
U-Boot mailing list U-Boot@lists.denx.de http://lists.denx.de/mailman/listinfo/u-boot