On 9/20/23 14:42, Paul Barker wrote:
On the Renesas RZ/G2L SoC family, we must ensure that the required clock signals are enabled and the reset signal is de-asserted before we try to communicate with the SDHI module.
Signed-off-by: Paul Barker paul.barker.ct@bp.renesas.com Reviewed-by: Biju Das biju.das.jz@bp.renesas.com Reviewed-by: Lad Prabhakar prabhakar.mahadev-lad.rj@bp.renesas.com
drivers/mmc/renesas-sdhi.c | 61 ++++++++++++++++++++++++++++++++++++++ 1 file changed, 61 insertions(+)
diff --git a/drivers/mmc/renesas-sdhi.c b/drivers/mmc/renesas-sdhi.c index 8e716f74491f..170c5dcc2ebe 100644 --- a/drivers/mmc/renesas-sdhi.c +++ b/drivers/mmc/renesas-sdhi.c @@ -20,6 +20,7 @@ #include <linux/io.h> #include <linux/sizes.h> #include <power/regulator.h> +#include <reset.h> #include <asm/unaligned.h> #include "tmio-common.h"
@@ -964,6 +965,8 @@ static int renesas_sdhi_probe(struct udevice *dev) u32 quirks = dev_get_driver_data(dev); struct fdt_resource reg_res; DECLARE_GLOBAL_DATA_PTR;
struct clk imclk2, aclk;
struct reset_ctl rst; int ret;
priv->clk_get_rate = renesas_sdhi_clk_get_rate;
@@ -1012,6 +1015,49 @@ static int renesas_sdhi_probe(struct udevice *dev) goto err_clkh; }
- if (IS_ENABLED(CONFIG_RZG2L)) {
/*
* On members of the RZ/G2L SoC family, we need to enable
* additional chip detect and bus clocks, then release the SDHI
* module from reset.
*/
This could use a separate function, and then, use bulk clock API via clk_get_bulk() and co .
ret = clk_get_by_name(dev, "cd", &imclk2);
if (ret < 0) {
dev_err(dev, "failed to get imclk2 (chip detect clk)\n");
goto err_get_imclk2;
}
[...]