Hi,
On 06/07/2018 09:14 AM, Jagan Teki wrote:
- Add few imx maintainers
On Thu, Jun 7, 2018 at 12:25 PM, Hannes Schmelzer hannes@schmelzer.or.at wrote:
hi,
i'm actually trying to convert my i.mx6 boards to DM, many things are already doing well. But I've trouble getting the console (UART) runnin SPL.
The "preloader_console_init" is called very early in board_init_f, i guess that DM isn't ready at this point.
has anyone experience in this?
Yes I've faced the same, look like DEBUG Uart doesn't support low level init. Peng or someone can explain more.
When converting the OPOS6UL to DM, I had to move the preloader_console_init call into the spl_board_init function.
Regards,
Jagan.
--
Sébastien Szymanski
Software engineer, Armadeus Systems
Tel: +33 (0)9 72 29 41 44
Fax: +33 (0)9 72 28 79 26