On Friday 09 May 2008, Wolfgang Denk wrote:
From: Sergei Poselenov sposelenov@emcraft.com
Signed-off-by: Sergei Poselenov sposelenov@emcraft.com Signed-off-by: Wolfgang Denk wd@denx.de
board/syscon3/syscon3.c | 25 +++++++++++++++++++ include/configs/syscon3.h | 58 +++++++++++++++++++------------------------- 2 files changed, 50 insertions(+), 33 deletions(-)
I can't find this board support. And also no patches for it.
Please find some further comments below.
diff --git a/board/syscon3/syscon3.c b/board/syscon3/syscon3.c index ea33f82..b814bae 100644 --- a/board/syscon3/syscon3.c +++ b/board/syscon3/syscon3.c @@ -33,6 +33,8 @@ #include <asm/immap_85xx.h> #include <ioports.h> #include <flash.h> +#include <libfdt.h> +#include <fdt_support.h>
DECLARE_GLOBAL_DATA_PTR;
@@ -184,3 +186,26 @@ int board_early_init_r (void) return (0); } #endif /* CONFIG_BOARD_EARLY_INIT_R */
+#if defined(CONFIG_OF_LIBFDT) && defined(CONFIG_OF_BOARD_SETUP) +void +ft_board_setup(void *blob, bd_t *bd) +{
- u32 val[4];
- int rc;
- ft_cpu_setup(blob, bd);
- /* Fixup NOR mapping */
- val[0] = 0; /* chip select number */
- val[1] = 0; /* always 0 */
- val[2] = gd->bd->bi_flashstart;
- val[3] = gd->bd->bi_flashsize;
- rc = fdt_find_and_setprop(blob, "/localbus", "ranges",
val, sizeof(val), 1);
- if (rc)
printf("Unable to update property NOR mapping, err=%s\n",
fdt_strerror(rc));
+} +#endif /* defined(CONFIG_OF_LIBFDT) && defined(CONFIG_OF_BOARD_SETUP) */
This is not needed anymore. With my latest patch (available in the u-boot-ppc4xx repository, master branch for pulling):
[PATCH 2/3] ppc4xx: Add weak default ft_board_setup() routine
this board specific code is not needed in this case, since it is an exact copy of the weak default routine. Please remove it in the next version of this patch.
Thanks.
Best regards, Stefan
===================================================================== DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: +49-8142-66989-0 Fax: +49-8142-66989-80 Email: office@denx.de =====================================================================