9 Feb
2018
9 Feb
'18
11:13 a.m.
To match the iomux setting of uart2 at SPL, correct the uart2 default pin configuration, if not changed, the evb-rk3229 can't output the log message.
Signed-off-by: David Wu david.wu@rock-chips.com
arch/arm/dts/rk322x.dtsi | 11 +++++++++-- 1 file changed, 9 insertions(+), 2 deletions(-)
Acked-by: Philipp Tomsich philipp.tomsich@theobroma-systems.com