28 Feb
2022
28 Feb
'22
8:08 p.m.
When SPI flash is used in SPL there is no console, so ctrlc() cannot be called. Add a condition to fix this.
Signed-off-by: Simon Glass sjg@chromium.org ---
drivers/mtd/spi/spi-nor-core.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/mtd/spi/spi-nor-core.c b/drivers/mtd/spi/spi-nor-core.c index a70fbda4bb..3b7c817c02 100644 --- a/drivers/mtd/spi/spi-nor-core.c +++ b/drivers/mtd/spi/spi-nor-core.c @@ -929,7 +929,7 @@ static int spi_nor_erase(struct mtd_info *mtd, struct erase_info *instr)
while (len) { WATCHDOG_RESET(); - if (ctrlc()) { + if (!IS_ENABLED(CONFIG_SPL_BUILD) && ctrlc()) { addr_known = false; ret = -EINTR; goto erase_err;
--
2.35.1.574.g5d30c73bfb-goog