4:14 p.m.
According to 8MM/MN/MP reference manual, their pad registers only have 4 valid DSE values. And DSE2 and DSE4 are different with current definitions in iomux-v3.h. Fix the issue to align with manual. Signed-off-by: Ye Li ye.li@nxp.com Acked-by: Peng Fan peng.fan@nxp.com
Applied to u-boot-imx, master, thanks !
Best regards, Stefano Babic
--
=====================================================================