On Sat, Feb 04, 2023 at 07:34:46AM +0100, Jan Kiszka wrote:
On 03.02.23 19:51, Tom Rini wrote:
On Fri, Feb 03, 2023 at 01:26:37PM +0100, Jan Kiszka wrote:
From: Jan Kiszka jan.kiszka@siemens.com
There are many ways to get a signed firmware for the IOT2050 devices, namely for the parts under user-control. This script documents one way of doing it, given a signing key. Augment the board documentation with the required procedure around it.
Signed-off-by: Jan Kiszka jan.kiszka@siemens.com
[snip]
+# currently broken in upstream +#source/tools/binman/binman replace -i flash.bin -f fit@0x380000.fit fit@0x380000 +dd if=fit@0x380000.fit of=flash.bin bs=$((0x1000)) seek=$((0x380000/0x1000)) conv=notrunc
Is that still a true comment?
binman: Node '/fit@0x380000/images/u-boot': Offset 0x0 (0) size 0xb8870 (755824) is outside the section '/fit@0x380000' starting at 0x0 (0) of size 0x400 (1024)
And for the second call:
binman: Node '/fit@0x380000': Replacing sections is not implemented yet
We tried fixing but eventually had to give up. binman is not easy to understand in these corners.
OK, thanks.