This splits the compilation of code modules for TPL and SPL for OF_CONTROL (and related) features between TPL and SPL. The typical use-case of this is a TPL stage that uses OF_PLATDATA at TPL and provides full OF_CONTROL at SPL (e.g. on the RK3368).
Signed-off-by: Philipp Tomsich philipp.tomsich@theobroma-systems.com
Reviewed-by: Simon Glass sjg@chromium.org Reviewed-by: Tom Rini trini@konsulko.com
Changes in v4: None Changes in v3: None Changes in v2: None
lib/Makefile | 10 +++++----- 1 file changed, 5 insertions(+), 5 deletions(-)
Applied to u-boot-rockchip, thanks!