16 Jan
2018
16 Jan
'18
3:56 p.m.
On 10 January 2018 at 23:15, Heinrich Schuchardt xypron.glpk@gmx.de wrote:
CloseProtocol cannot be called without agent handle.
There is no need to close the device path protocol if it has been opened without agent handle.
Signed-off-by: Heinrich Schuchardt xypron.glpk@gmx.de
v3 no change v2 no change
lib/efi_selftest/efi_selftest_devicepath.c | 8 ++++---- 1 file changed, 4 insertions(+), 4 deletions(-)
Reviewed-by: Simon Glass sjg@chromium.org