1 Aug
2017
1 Aug
'17
11:48 a.m.
On 28 July 2017 at 10:31, Philipp Tomsich philipp.tomsich@theobroma-systems.com wrote:
There is no reasonably robust way (this will be needed so early that diagnostics will be limited) to specify the base-address of the secure timer through the DTS for TPL and SPL. In order to allow us a cleaner way to structure our SPL and TPL stage, we now move to a DM timer driver.
Signed-off-by: Philipp Tomsich philipp.tomsich@theobroma-systems.com
configs/lion-rk3368_defconfig | 4 ++++ 1 file changed, 4 insertions(+)
Reviewed-by: Simon Glass sjg@chromium.org