14 Aug
2024
14 Aug
'24
1:52 p.m.
Hi Heiko,
On Wed, Aug 14, 2024 at 1:11 AM Heiko Schocher hs@denx.de wrote:
Hmm.. yes, setting a default value is a good option, so I would add a check, if define is not set yet?
And we should simply let the name "CFG_IMX6_PWM_PER_CLK" ?
Yes, that is OK.
If okay, I can make a v3 if you want?
Yes, please send a v3.
Thanks,
Fabio Estevam