Hello Stefan,
Am 26.03.2019 um 13:16 schrieb Stefan Roese:
This patch fixes the timer register setup in at91_wdt_start() to correctly configure the register again. The input timeout value is now in milli-seconds instead of seconds with the new watchdog API. Make sure to take this into account and only use a max timeout value of 16 seconds as appropriate for this SoC.
Also the check against a lower timeout value than 0 is removed. This check makes no sense, as the timeout value is unsigned.
Signed-off-by: Stefan Roese sr@denx.de Reported-by: Heiko Schocher hs@denx.de Cc: Heiko Schocher hs@denx.de Cc: Andreas Bießmann andreas@biessmann.org Cc: Eugen Hristev eugen.hristev@microchip.com
v2:
No change
drivers/watchdog/at91sam9_wdt.c | 26 ++++++++++++++------------ 1 file changed, 14 insertions(+), 12 deletions(-)
Thanks!
Reviewed-by: Heiko Schocher hs@denx.de Tested on the taurus board: Tested-by: Heiko Schocher hs@denx.de
bye, Heiko