2 Jan
2014
2 Jan
'14
5:20 p.m.
On 26/12/2013 17:51, Fabio Estevam wrote:
From: Fabio Estevam fabio.estevam@freescale.com
When changing LDO voltages we need to wait for the required amount of time for the voltage to settle.
Also, as the timer is still not available when arch_cpu_init() is called, we need to call it later at board_postclk_init() phase.
Signed-off-by: Fabio Estevam fabio.estevam@freescale.com
Applied to u-boot-imx, thanks !
Best regards, Stefano Babic
--
=====================================================================
DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: +49-8142-66989-53 Fax: +49-8142-66989-80 Email: sbabic@denx.de
=====================================================================