The i.MX51 has a single USB PHY clock, while the i.MX53 has two. These 3 clocks have different clock gate control bit-fields.
The existing code was correct only for i.MX53, so this patch fixes the i.MX51 use case.
Signed-off-by: Benoît Thébaudeau benoit.thebaudeau@advansee.com Cc: Stefano Babic sbabic@denx.de Cc: Marek Vasut marex@denx.de Cc: Jana Rapava fermata7@gmail.com Cc: Wolfgang Grandegger wg@denx.de Cc: Igor Grinberg grinberg@compulab.co.il
Sweet find :-)
Reviewed-by: Marek Vasut marex@denx.de
Best regards, Marek Vasut