On Thu, Aug 29, 2024 at 07:04:36PM -0600, Simon Glass wrote:
Hi Tom,
On Thu, 29 Aug 2024 at 10:59, Tom Rini trini@konsulko.com wrote:
On Thu, Aug 29, 2024 at 09:01:17AM -0600, Simon Glass wrote:
Hi Neil,
On Thu, 29 Aug 2024 at 08:26, neil.armstrong@linaro.org wrote:
On 29/08/2024 00:08, Simon Glass wrote:
Send the Labgrid quit characters to ask it to exit gracefully. This typically allows it to power off the board being used.
Sending those characters every time could collide with other CI systems, I don't think it's a good idea.
What systems are you thinking about and what sort of collision would occur?
What do you suggest instead?
Why do we need this at all? Did I miss where we send picocom the disconnect nicely key-combination?
When labgrid gets a signal, it exits. It doesn't continue its co-routines and execute the end strategy to power things off, etc. I suspect it could be made to do that, but I already have 62 Labgrid patches, so I thought this would be expedient...
I can make this conditional on the new USE_LABGRID variable.
It sounds to me like we need to make generic improvements to our hooks then, if there's not a "now call poweroff" hook.