Hello Tommaso,
Am Samstag, dem 08.01.2022 um 20:08 +0100 schrieb Tommaso Merciai:
On Tue, Jan 04, 2022 at 11:04:10AM +0000, Teresa Remmet wrote:
Hello Tommaso,
Am Samstag, dem 25.12.2021 um 21:25 +0100 schrieb Tommaso Merciai:
This function defined for two architecture is not really generic and can generate problem when people add a new board.
Signed-off-by: Tommaso Merciai tomm.merciai@gmail.com
arch/arm/mach-imx/imx8m/soc.c | 39 ---------------------------
1 file changed, 39 deletions(-)
diff --git a/arch/arm/mach-imx/imx8m/soc.c b/arch/arm/mach- imx/imx8m/soc.c index 863508776d..f0030a557a 100644 --- a/arch/arm/mach-imx/imx8m/soc.c +++ b/arch/arm/mach-imx/imx8m/soc.c @@ -1313,45 +1313,6 @@ void do_error(struct pt_regs *pt_regs, unsigned int esr) #endif
#if defined(CONFIG_IMX8MN) || defined(CONFIG_IMX8MP) -enum env_location env_get_location(enum env_operation op, int prio) -{
- enum boot_device dev = get_boot_device();
- enum env_location env_loc = ENVL_UNKNOWN;
- if (prio)
return env_loc;
- switch (dev) {
-#ifdef CONFIG_ENV_IS_IN_SPI_FLASH
- case QSPI_BOOT:
env_loc = ENVL_SPI_FLASH;
break;
-#endif -#ifdef CONFIG_ENV_IS_IN_NAND
- case NAND_BOOT:
env_loc = ENVL_NAND;
break;
-#endif -#ifdef CONFIG_ENV_IS_IN_MMC
- case SD1_BOOT:
- case SD2_BOOT:
- case SD3_BOOT:
- case MMC1_BOOT:
- case MMC2_BOOT:
- case MMC3_BOOT:
env_loc = ENVL_MMC;
break;
-#endif
- default:
-#if defined(CONFIG_ENV_IS_NOWHERE)
env_loc = ENVL_NOWHERE;
-#endif
break;
- }
- return env_loc;
-}
#ifndef ENV_IS_EMBEDDED long long env_get_offset(long long defautl_offset)
would it not make sense to move also env_get_offset() to board level?
Hi Teresa, I think is better to put this function at board level. In this way others boards that use i.MX8MN/i.MX8MM SOC can customize env_get_location function. For example: maybe one user want store U-Boot env on a device other than the boot device.
Michael send a patch to remove the function. Which I missed. See: https://lore.kernel.org/u-boot/20211117143456.34441-1-michael@amarulasolutio...
So everything is fine then.
Thanks, Teresa
Tommaso
Regards, Teresa
{