In message 42AFEBD3.3050008@imc-berlin.de you wrote:
there's a terrible bug in the current U-Boot CVS concerning DDT:
For temperature below zero the function dtt_get_temp() (at least for lm75) returns wrong values!
... DTT: 1 is 235 C LCD: Hitachi TX14D11 5,7" 320x240 TFT (235°C) WDT: disabled
This is because of the use of an "int" although the lm75 only returns two byte ("signed short").
Ummm...
This trivial fix is needed:
Wait a moment...
--- u-boot/dtt/lm75.c 27 Jun 2003 21:32:38 -0000 1.2 +++ u-boot/dtt/lm75.c 15 Jun 2005 08:44:21 -0000 @@ -174,7 +170,7 @@
int dtt_get_temp(int sensor) {
- return (dtt_read(sensor, DTT_READ_TEMP) / 256);
- return ( ((signed short) dtt_read(sensor, DTT_READ_TEMP)) / 256);
This is not the right way to fix it. I reject this patch.
dtt_read() is declared to return "int", so no such cast should be needed, i. e. you fix the symptoms instead of the cause.
I think the patch must be done in dtt_read(); IMO the line
return ((int)((short)data[1] + (((short)data[0]) << 8)));
is wrong; it should read
return ((short)((short)data[1] + (((short)data[0]) << 8)));
or, even better,
short rc_s; ... rc_s = (short)data[1] + (((short)data[0]) << 8); return (rc_s);
And the same problem is with dlen == 1 - it should read
return ((signed char)data[0]);
Do you agree with this assessment? And can you please confirm that my suggested patch fixes your problem, too?
Best regards,
Wolfgang Denk