On 21/03/2013 09:03, Dirk Behme wrote:
Reviewing the ECSPI reset handling shows two issues:
Hi Dirk,
agree completely, only a very minor question..
- reg_ctrl = reg_read(®s->ctrl);
As you says, it makes no sense to read back the value of the register, also because reg_ctrl is overwritten some lines later ;-)
Best regards, Stefano Babic
--
=====================================================================