Hi Marek,
On 5/9/23 16:32, Lukasz Majewski wrote:
This option sets the current limit for 5V source to zero, so all the PMU outputs are primarily powered from battery source (DCDC_BAT).
This option may be set on systems, where the 5V is NOT supposed to be in any scenario powering the system - for example on systems where DCDC_BAT is connected to fixed and regulated 4.2V source (so the "battery" is not present).
Is it possible to dig this information out of DT or is the DT not available in SPL for this platform ?
This platform uses only SPL_OF_PLATDATA to keep the SPL size < 40 KiB.
I would prefer to keep this as Kconfig as the PMU driver is not supporting DT and in fact now ARCH_MX28 only has two boards supported - XEA and imx28evk.
Best regards,
Lukasz Majewski
--
DENX Software Engineering GmbH, Managing Director: Erika Unter HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-59 Fax: (+49)-8142-66989-80 Email: lukma@denx.de